5300-34
Terra Part # 5300-34
$85,388
Usually ships in 15-19 business days

Want it faster ? Read about FasTrak

Accessories related to Terra Part # 5300-34
78690
Spectrometer; 163 to 950 nm, Circular Dichroism, J 1500, Standard PMT, Jasco, 100/240 V
Product Details
  • Flexible model with a 163-950 nm wavelength range and a PMT detector (optional InGaAs)
  • High sensitivity measurements in near-/far-UV regions; includes Spectra Manager software
  • Light Source: 150W air-cooled Xe lamp (J-1500-150) or 450W water-cooled Xe lamp (J-1500-450)
  • Enhanced Vacuum UV-Measurement down to 163 nm
  • •  Optional HTCD auto sampling obtains up to 192 measurements without user intervention
  • Sample Compartment size: 150 W x 310 D x 165 H mm
  • Monochromator: Double-prism polarizing monochromator
  • Wavelength Range: 163 to 950 nm
  • Wavelength Accuracy: ±0.1 nm (163 to 250 nm), ±0.2 nm (250 to 500 nm), ±0.5 nm (500 to 800 nm), ±1.5 nm (800 to 950 nm)
  • Wavelength Reproducibility: ±0.05 nm (163 to 500 nm), ±0.1 nm (500 to 800 nm), ±0.5 nm (800 to 950 nm)
  • Spectral Bandwidth: 0.01 to 16 nm
  • Digital Integration Time: 0.1 msec to 30 sec
  • Scanning Speed: up to 10,000 nm/min
  • RMS Noise: 0.004 mdeg (185nm, 150W), 0.003 mdeg (185nm, 450W), 0.007 mdeg (200, 500 nm)
  • Baseline Stability: 0.02 mdeg/hr
  • Power Consumption: 315 VA
  • Applications: Protein conformational studies, Protein folding studies, DNA / RNA interactions, Enzyme kinetics, Formulation studies, Purity testing of optically active substances, Quantitative analysis of pharmaceuticals, Natural products chemistry, Material science, Rapid kinetics (stopped-flow) CD, Absorbance and fluorescence studies
  • Integrated validation mode
  • Features and benefits: double prism monochromator provides low stray light, high optical throughput, highly efficient nitrogen purge system, digital signal processing, simultaneous multi-probe, wavelength calibration with integrated Hg lamp, measures micro-volume samples, scanning modes, high signal-to-noise ratio, collimated sample beam, automated titration and stopped-flow
  • Light Source for Validation: Integrated Mercury lamp
  • Wavelength Resolution: 0.025 nm
  • Slit Width: 1 to 4000 μm
  • Measurement Mode: Continuous scan, step scan, auto-scan
  • CD Full Scale: ±8000 mdeg
  • CD Resolution: 0.00001 mdeg
  • CD Dynamic Range: No CD distortion even with an OD=3 sample in the optical path
  • Stray Light: less than 0.0003% (at 200 nm)
  • LD Measurement: Included as standard, Full scale ±1 ΔOD
  • UV Measurement: Included as standard, Full scale up to 5 Abs
  • External Input Terminals: Two channels (input range: -1 to 1 V DC):
  • Nitrogen Gas Purge: High efficiency N2 purge with internal optimization for light source unit, monochromator unit and sample compartment
  • Accessory Auto-Recognition: Standard
  • Communication / Control: USB 2.0 / Spectra Managerâ„¢ or Spectra Managerâ„¢ CFR
  • Options and Accessories (inquire for details):
  • HTCD Plus High-Throughput CD/LD/Absorbance System  (for J1500)              
  • High Throughput CD (HTCD) ASU-800, ASP-849 (for J1500)
  • Light Source: 20W Halogen lamp, 150W air-cooled Hg-Xe lamp
  • Detector: InGaAs
  • Spectra Manager CFR software for 21 CFT Part 11 compliance
  • Temperature control: Single- (PTC-510, 514, 517 ) and Multi-Position (MPTC-511, 513) Peltier Cell Holders,  Temperature-Wavelength Scan (HTC-572, CAP-500)
  • Extended Wavelength: EXPM-531 (PMT), EXIG-532 (InGaAs)
  • Microsampling Disk (MSD-462), Capillary Cell Jacket (CAP-500)
  • Automated Titration Unit(ATS-530; Stopped-Flow System SFS-602
  • Total Fluorescence and Fluorescence Scanning (FMO-522, FDT-538)
  • Other accessories: Magnetic CD, Couette Flow Cell Unit CFC-573, Optical Rotatory Dispersion ORDM-(520, ORDE-521)
  • Additional software options: Multivariate SSE Analysis Program JWMVS-529, Interface for CDPro Secondary Structure Analysis, Denatured Protein Analysis Program JWTDA-519, Protein-Ligand Analysis Program JWPLB-525, Curve Fitting Program JWCVF-518, Macro Command Program JWMCR-512
  • Other Instruments: Vibrational Circular Dichroism FVS-6000, Circularly Polarized Luminescence CPL-300, Digital Polarimeter
  • P-2000

• Spectrometer Type: Circular Dichroism

• Peltier Detector: Standard PMT

• Brand: J-1000 Series

• Manufacturer SKU: 7000-J005A

• Wavelength Range: 163 to 950 nm

• Unit of Measure: EA

• Electrical Specifications: 100/240 V, 50/60 Hz

• Weight, Product: 180.77 lb

• Dimensions, Product: 41.53" W x 21.45" D x 15.35" H

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.