RapidVap N2 and N2/48 Dry Evaporation Systems combine vortex motion, dry heat and nitrogen blow down for fast evaporation rates
N2 models for moderate sample throughput with end-point determination include an 8-place sample block, introduces nitrogen to tubes in sets of two and access up to 450 mL of samples per tube
N2/48 models for small to moderate sample throughput with a 48 sample capacity introduce nitrogen in clusters of six
Select models available with an RS-232 Link for remote control of functions from a user-supplied computer
FreeZone Freeze Dry Systems by Labconco with a corrosion resistant PTFE-coated collector coil have a brushed stainless steel and glacier white, powder-coated steel exterior.
Polypropylene
Opaque, resistant to most acids, solvents and alcohol-based cleaners.
Fiberglass
Fiber glass is strong, long-lasting, non-conductive, radio frequency transparent, and it also absorbs sound waves.
Coated Steel
Offers excellent corrosion and chemical resistance while extending the life of the Steel
Epoxy Resin
Epoxy Resin; tested resistance to: damage from common organic compounds and volatile/non-volatile chemicals, bacteria and fungus; Heat deflection up to 325°F (167.2°C); Self-extinguishing surface; Non-absorbent and corrosion resistant; Non-reactive and low-sheen uniform finish
Glass
The non-porous surface of glass is easy to clean and resists most detergents, but electrostatic charges may accumulate on its surface
Powder-Coated Steel
Powder Coated Steel; More economical than stainless steel; offers excellent corrosion and chemical resistance while extending the life of the Steel
Powder Coated Steel
More economical than stainless steel; offers excellent corrosion and chemical resistance
PVC
Clear, chemical resistant
Stainless Steel
Stainless Steel is corrosion resistant, durable, and easy to clean. (see product details for specific Stainless Steel Grade)
Designated for use with BSL Class I and II organisms, such as E.coli. 70% of air is recirculated within the hood, 30% of the air is exhausted through a HEPA filter.
Class II B2
Protects users, products and environments from hazardous agents that require Biosafety Level 1, 2 or 3 containment. Dedicated exhaust system and remote blower discharge 100% of filtered exhaust air. Suitable for use with hazardous chemicals and fumes.
Class II C1
Toggle between A2 and B2 configurations. Protects personnel, product and lab environment by maintaining complete containment in event of exhaust system failure. For Biosafety Level (BSL) 1, 2, and 3 containment or BSL 4 with PPE
Provides the same filtration as ducted model. Ductless fan filter units (FFUs) can be placed in any lab space without consideration of adding ductwork or major utilities. Ductless FFUs cut energy bills by filtering and recirculating heated or cooled air back into the laboratory. This means that unlike ducted FFUs, which constantly send treated air outside the facility, ductless FFUs keep more treated air inside of the facility and reduce the load on the HVAC utilities.
Standard
Removes surface-deposited particles from personnel with class 100 HEPA filtered air prior. Uniform pattern of nozzles arranged on walls and ceiling ensures effective distribution of filtered air; contaminated air exhausted through wall-mounted vents. Programmable, solid-state microprocessor panel controls access door.
Light Fixture
LED and fluorescent models available, in 4' x 2' ceiling-mount panels or LED strips for mounting on ceiling T-bars
Compact Labconco CentriVap micro IR Vacuum Concentrators have a 24-tube capacity and are available with High Capacity Micro Rotors or Teflon-Coated Aluminum Rotors
Purifier Axiom
Ergonomic Purifier Axiom units convert between Type A and Type B Mode for use in BSL 1,2 and 3 labs; available in 4 ft. and 6 ft. models with sash openings of 8" and 10"
Purifier Logic+
Purifier Logic+ discharges 100% of filtered exhaust air from work area via a dedicated exhaust system and remote blower; models need to be hard ducted to the outside
RapidVap
RapidVap N2 and N2/48 Dry Evaporation Systems by Labconco combine vortex action, heat, and nitrogen blow-down to speed evaporation
Directs heat and nitrogen gas downward onto the surface of the sample; reduces partial pressure directly over the liquid to speed evaporation and helps remove solvents.
Freeze dry systems for low eutectic point samples have a working temperature of -86°C. Benchtop and console Lyophilizers are available in a range of capacities.
Freestanding, undercounter and ADA compliant labware washers are designed for use with beakers and other wide-mouth general purpose lab glasswares. Labconco SteamScrubber and FlaskScrubbers are versatile units with an array of accessories to accommodate various glassware heights.
Flasks
Narrow-neck glasswares such as flasks require a lab washer with spindles. FlaskScrubber Washers by Labconco feature spindles and a patented vacuum drying system that ensures flasks are completely dry.
Produces an ultrapure inert atmosphere for materials sensitive to moisture and/or oxygen by circulating an inert gas and removing oxygen and moisture inside the glovebox.