120/240 V Benchtop GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136146 UV/UF-TOC 1714-53 $11,993 10-20 Days2
Ships Free Free shipping in contiguous USA
120/240 V Benchtop GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136151 UV/UF 1714-50 $11,366 10-20 Days3
Ships Free Free shipping in contiguous USA
120/240 V Benchtop GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136152 UV 1714-48A $10,877 5-5 Days4
Ships Free Free shipping in contiguous USA In stock
120/240 V Benchtop GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136153 UV-TOC 1714-52 $11,366 10-20 Days5
Ships Free Free shipping in contiguous USA
120/240 V Wall Mount GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136169 UV/UF 1714-55A $11,366 5-5 Days6
Ships Free Free shipping in contiguous USA In stock
120/240 V Wall Mount GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136170 UV 1714-57 $10,808 10-20 Days7
Ships Free Free shipping in contiguous USA
120/240 V Wall Mount GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136171 UV-TOC 1714-58 $11,366 10-20 Days8
Ships Free Free shipping in contiguous USA
120/240 V Wall Mount GenPure xCAD Plus 1-5 ppb 31.7 Gal/hr <0.001 EU/mL 50136172 UV/UF-TOC 1714-59 $11,993 10-20 Days9
Ships Free Free shipping in contiguous USA
Voltage
Configuration
Model
Total Organic Carbon
Water Production Rate
Endotoxin Removal
Manufacturer SKU
System Features
Item ordered before. Click on bagde to see the order.

Up to 30-day trial periods, free return shipping and on-site training available for qualified equipment.

Request demo from your product specialist or add note to your order or quote request.

* *
*See discounts and promos in cart Web-exclusive discount applies only to quotes/orders placed directly on our website; not valid for phone, email, or other ordering methods.
*includes web discount for online orders Web-exclusive discount applies only to quotes/orders placed directly on our website; not valid for phone, email, or other ordering methods.
Custom-configured product. Contact Lab Equip by phone, chat or email for a project-specific quote.
Custom-configured product. Contact Lab Equip by phone, chat or email for a project-specific quote.
Free shipping in contiguous USA
Some ship in:
Usually Ships in:
Product Details
Product Details
  • Barnstead GenPure xCAD Plus Ultrapure Water Purification Systems in benchtop and wall mount models simultaneously dispenses up to 3 remote dispensers
  • Water purifier delivers up to 200 liters a day of ultrapure Type 1 water
  • Available in Ultrafiltration (UF), Ultraviolet (UV) Intensity Monitoring and Total Organic Compound Monitoring (TOC) systems
  • GLP-Compliant model exceed ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW international standards
  • Includes Extended Control and Dispenser (xCAD) with an action radius of 32 inches delivers precise volume dosing at the press of a button for fully automatic volume control
  • Features: simultaneous dispensing, integrated feed water monitoring, leak detection, automatic volume control and feed water monitoring
  • Flow rate, max.: Up to 2L/min.
  • Operating pressure min. /max. : 29-87 psi (2 to 6 bar)
  • Conductivity: 0.055µS/cm
  • Resistance at 25°C: 18.2MW?cm
  • Bacterial content (CFU/mL) : <1
  • Particles >0.2µM/mL: <1
  • Feed Water Connector: 3/4 in. radius of hose connector
  • Temperature min./max. : 2° - 35°C
Features & Benefits

Features & Benefits

Learn More: GenPure xCAD

Additional Features of Barnstead GenPure xCAD Plus

  • Ultraviolet (UV) Oxidation effectively prevents bacterial contamination and oxidizes organics to produce pure water with low TOC levels; prevents risk of false TOC value as a result of diminished UV intensity; combination of 185/254 nm oxidizes organic compounds and allows for total oxidizable carbon levels of less than 5 ppb ideal for applications requiring extremely low levels of organics
  • Ultrafiltration (UF) removes molecules (pyrogens, nucleases, microorganisms and particulates) above their rated size; ideal for tissue culture, cell culture and media separation
  • Combination of Ultraviolet Oxidation and Ultrafiltration (UV/UF) produces water virtually free of all impurities; removes nucleases such as RNase and DNase and pyrogens; produces water with low TOC and pyrogen levels
  • Online Total Organic Carbon (TOC) with UV Intensity monitors real-time continual measurement of organic substances present in the water; continuously monitors UV intensity and removes risk of false TOC values caused by diminished UV intensity; alerts user when UV lamp is insufficient for accurate TOC measurements
  • All models exceed international standards ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW
  • Bench and wall mount models include mounting bracket up to 8 ft. (2.5 m) from main unit; bench models can be mounted under bench
  • Electronic dosing with automatic volume control of 0.01-65 L with <2% accuracy
  • Integrated feed water monitoring measures water conductivity with measuring cell and immediately displays fault message if quality of feed water drops below set value
  • Conductivity cells carefully calibrated before each measurement with built-in reference resistance with cell constants at 0.01 cm-; platinum chip sensor measures temperature with ± 0.1°C accuracy
  • Aquastop quick connect allows cartridge replacement within seconds between uses and in mid-operation; one part number ordering
  • Suitable for applications requiring Type 1 ultrapure water: life sciences and analytical chemistry
  • Ergonomic design with tilting display and swivel arm
  • Models are ready to use
GLP-compliant documentation
  • Operating system protected by real-time clock and code prevents unauthorized changes to system settings
  • Safe data transfer of all measured data, faults, date and time to a PC computer or log printer with RS-232 interface with adjustable send
  • Digital microprocessor control automatically monitors and stores faults from last four weeks
  • On and off switch for USP-compliant conductivity measurement with temperature compensation
Feed Water Requirements
  • Source: Portable tap water, pretreated by reverse osmosis, ion exchange or distillation
  • Feed water conductivity, uS/cm: <2
  • TOC, ppb: Max 50
  • Bacteria count, CFU/ml: <100
  • Turbidity, NTU: <1.0
  • Temperature, C: 2-35
  • Pressure, psi (bar): 1.4-87 (0.1-6)
Specifications and Additional Features for Barnstead GenPure xCAD Plus
  • Benchtop xCAD Dimensions W x D x H in. (mm): 10.2 x 21 x 28.5 (260 x 530 x 725)
  • Wall Mount xCAD Dimensions W x D x H in. (mm): 10.2 x 21 x 25.8 (260 x 530 x 655)
  • Electrical Requirements: 90-240V, 50/60 Hz
  • Power Consumption: 0.1kW
  • Flow rate: Up to 2L/min.
  • Operating pressure, min. /max. 29-87 psi (2 to 6 bar)
  • Conductivity 0.055µS/cm
  • Resistance at 25°C 18.2MWΩcm
  • Bacterial content (CFU/mL) <1
  • Particles <0.2µM/mL <1
  • Feed Water Connector 3/4 in. radius of hose connector
  • Temperature min. /max. 2° - 35°C
Model GenPure xCAD Plus GenPure xCAD Plus
UV system
GenPure xCAD Plus
UF system
GenPure xCAD Plus
UV/UF system
GenPure xCAD Plus
UV - TOC system
GenPure xCAD Plus
UV/UF - TOC system
Applications AA, IC, ICP,
standard buffer
Inorganic and organic trace analysis, HPLC, ICP-MS, IC, TOC analysis Molecular biology,
microbiology, PCR, IVF, monoclonal
antibodies
Molecular biology, PCR, DNA, monoclonal antibodies,
cell culture media
Chemical analysis (trace analysis, HPLC, IC, ICP-MS, TOC measurements) Biosciences
(cell and tissue culture
media, PCR, DNA,
monoclonal antibodies)
Resistance at 25°C: MΩ.cm 18.2 for all models
Conductivity, µS/cm 0.055 for all models
TOC, ppb 5-10 1-5 5-10 1-5 1-5 1-5
Bacteria, CFU/mL <1 for all models
Particles, 0.22 µm/mL <1 for all models
Endotoxins, EU/mL n/a n/a <0.001 <0.001 n/a <0.001
TOC Monitor n/a n/a n/a n/a Standard Standard
Products similar to this one
Other products you may find relevant
Buy Accessories
Manuals & Resources

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.