Available Certified ISO Grade Designs: ISO 7, ISO 8
Solair particle counters in 6-ch and 8-ch models for cleanroom particle monitoring
Cleanroom certification ISO 21501-4 Compliant on Solair 1100ld, 3100 and 5100 models
Pass/fail report wizard for ISO-14644-1, EU GMP Annex 1, and FS-209E report formats
• Light source: Laser Diode or Extreme Life Laser Diode
Size range: from 0.1 um to 100.0 um
Solair 1100LD model features: 8-channels, sensitivity range from 0.1 - 1.0 μm, a 1.0 CFM (28.3 LPM) flow rate, designed for ISO Class 1 to Class 7 cleanrooms
Solair 3100 model features: 6-channels, sensitivity range from 0.3 - 25.0μm, a 1.0 CFM (28.3 LPM) flow rate; designed for ISO classes 1-8 cleanrooms
Solair 3350 model features: 6-channels, sensitivity range from 0.3 - 25.0 µm, a 100 LPM flow rate; designed for ISO classes 1-8 cleanrooms
Solair 5100 model features: 6-channels, sensitivity range from 0.5 - 25.0μm, a 1.0 CFM (28.3 LPM) flow rate; designed for ISO classes 1-8 cleanrooms
Solair Boulder model features: 6-channels, sensitivity range from 5.0 - 100.0 um and a 28.3 LPM flow rate
Light source: Long Life Laser Diode (1100LD), Extreme Life Laser Diode Technology with >20-year Mean Time To Failure (MTTF)
All models include: Operating Manual on CD; Isokinetic Sample Probe with Tripod and Tubing; Purge Filter; Power Cable and Spare Fuse; LMS XChange and Express Software; Printer; Printer Paper
Calibration Meets ISO 21501-4 calibration using NIST traceable PSL spheres, DMA and condensation Particle Counter Security: Integrated alarm buzzer and external alarm connector, alarms on counts, low battery, sensor failure
Sample Output
1100LD Model: Internally filtered to 100% @ 0.1 μm, optional HEPA filtration for cooling system exhaust
All other models: Internally filtered to HEPA standards (>99.97% @ 0.3 μm)
Features on all models: stainless steel enclosure; icon-driven 5.7 - inch (14.47 cm) color TFT touch screen display; USB, Ethernet, RS-485, Secure Data Transfer to and Storage on USB Flash Drive; automatic, manual, beep, concentration, cumulative/differential count modes; rotating buffer (includes particle and environmental data, location and time); Languages English (U.S.), French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean
Vacuum Source: Internal closed-loop controlled pump. Allows the use of 3/8" ID sample tubing of up to 12 meters (40 feet) @ 50 & 100L
Optional Environmental Sensors(up to 4) temperature/relative humidity, air velocity, differential pressure or others
Shows how to configure locations function on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Locations Function by LWSProvides detailed instructions on location functions settings on touchscreen display on Solair models
How to configure sample settings on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Sample Settings by LWSProvides detailed instructions on configuring sample settings on Solair model
How to configure alarm settings on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Alarm Settings by LWSProvides detailed instructions on configuring alarm settings on touchscreen display on Solair models
How to configure security settings on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Security Settings by LWSProvides detailed instructions on configuring security and password settings on touchscreen display on Solair models
Configure training reports for ISO compliance on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Training Reports Function by LWSProvides detailed instructions on steps to configure training reports on Solair models
Shows how to configure locations function on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Locations Function by LWSProvides detailed instructions on location functions settings on touchscreen display on Solair models
How to configure sample settings on Solair Airborne Particle Counter modelsSolair Airborne Particle Counter Tutorial on Sample Settings by LWSProvides detailed instructions on configuring sample settings on Solair model
Provide Terra with your desired ISO Grade design. We will tailor the product to meet your criteria and certify it with a report appended to your invoice. Certificate includes all the necessary information to streamline audits and facility compliance.
Protecting Personal Information
Terra is committed to ensuring that our customer’s personal information is secure. In order to prevent unauthorized access or disclosure, Terra has developed procedures to safeguard and secure information collected online and offline.
Global Customer Base
At Terra, we are committed to providing top-tier equipment to customers throughout the world. Over the past 5 years, clients in over 100 countries have purchased equipment from Terra.
Top-Tier Clients
Terra’s key customers include some of the largest research labs, production facilities and universities in the world