Summary

  • V-780 UV-Vis/NIR double beam Spectrophotometer with an InGaAs detector
  • Single Monochromator, dual gratings and high-speed scanning
  • •  Applications: absorbance, transmittance or reflectance measurements including liquids and solids
  • High-sensitivity PMT and variable spectral band-width
  • Offers increase S/N and excellent resolution for observing rotational peaks in vibrational spectrum
  • V-780 Specifications:
  • Spectral Bandwidth (SBM): UV-Visible: 0.1, 0.2, 0.5, 1, 2, 5, 10 nm; L2, L5, L10 nm (low stray light mode);  M1, M2 nm (micro cell mode)
  • Spectral Bandwidth (SBM): NIR: 0.2, 0.4, 0.5, 1, 2, 4, 10, 20; L4, L10, L20 nm (low stray light mode); M2, M4 nm (micro cell mode)
  • Light Source: Halogen lamp, Deuterium lamp (Light source exchange wavelength: Between 330 and 350 nm)
  • Baseline Stability: ±0.0003 Abs/hour
  • Optical System: Czerny-Turner grating mount, Single Monochromator. Fully symmetrical double-beam
  • Light Source: Halogen lamp, Deuterium lamp
  • Detector: PMT, Peltier cooled PbS
  • Wavelength Accuracy: +/-0.3 nm (at 656.1 nm), +/-1.0 nm (at 1312.2 nm)
  • Wavelength Repeatability: +/-0.05 nm (UV-Vis), +/-0.1 nm (NIR)
  • Scanning Speed: 10~4000 nm/min (8000 nm/min in preview mode)
  • Slew Speed: UV-Vis: 12,000 nm/min, NIR: 48,000 nm/min
  • Stray Light: 1 % (198 nm KCL 12 g/L aqueous solution), 0.005 % (220 nm NaI 10 g/L aqueous solution, 0.005 % (340 nm NaNO2 50 g/L aqueous solution), 0.005 % (370 nm NaNO2 50 g/L aqueous solution), SBW: L2nm, 0.04 % (1420 nm: H2O), SBW: L4 nm
  • Photometric Range: UV-Visible: -4~4 Abs; NIR: -3~3 Abs
  • Photometric Accuracy: +/-0.0015 Abs (0 to 0.5 Abs); +/-0.0025 Abs (0.5 to 1 Abs); +/-0.3 %T Tested with NIST SRM 930D
  • Photometric Repeatability: +/-0.0005 Abs (0 to 0.5 Abs), +/-0.0005 Abs (0.5 to 1 Abs), Tested with NIST SRM 930D
  • RMS Noise: 0.00003 Abs; (0 Abs, wavelength: 500 nm, measurement time: 60 sec, SBW :2 nm)
  • Baseline Flatness: +/-0.0002 Abs (200 - 1600 nm)
  • Baseline Stability: 0.0003 Abs/hour, 0.04 % (220 nm NaI 10 g/L aqueous solution), 0.02 % (340 nm NaNO2 50 g/L aqueous solution), 0.02 % (370 nm NaNO2 50 g/L aqueous solution), (10 mm cell); ±0.0004 Abs/hour, (Wavelength: 250 nm, response: slow and SBW: 2nm.)
  • Detector: Photomultiplier tube, Peltier cooled InGaAs photodiode
  • Standard Programs: Abs/%T meter, Quantitative analysis, Spectrum measurement, Time course measurement, Fixed wavelength measurement, Validation, Daily Check, Two wavelength time course measurement
  • Features on all models: reduced noise and stray light with sophisticated electronic and optical design, delivers fast scanning without wavelength tracking errors, dark correction with stray light reduction, reliable peak assignment, user-friendly operation, analog output, IQ start button provides comprehensive validation to USP, EP and JP
  • Accessories (inquire for pricing and additional information): Automatic Peltier Multi-Cell Holders, Peltier Thermostatted Single Cell Holders, Constant Temperature Cell Holders/Cell Changers, Liquid and Film Cell Holders/Cell Changers, Temperature Control Accessories, Micro-Volume Liquid Transmission Cell Holders, Optical Fiber Units, Integrating Spheres, Absolute Reflectance, Specular Reflectance, Autosampler, Sippers, Flow Cells, Spectra Manager Software Suite, iRM-1000 Intelligent Remote Module, Standard Measurement Programs, Optional Programs,

Specifications

Wavelength Range: 190-1600 nm

Design: InGaAs Detector

Manufacturer SKU: 7067-J054A

Unit of Measure: EA

Helena

Weight, Product: 63.9341 lb

Dimensions, Product: 18.11" W x 23.7" D x 10.55" H

Other products you may find relevant
Copyright 1999 - 2024 Terra Universal. Inc. All rights reserved.