Learn More: Advanced Security Features

Dual Convection Technology of Heratherm Advanced Protocol Security Incubators

Dual Convection Technology combines the function of gravity convection and mechanical convection systems to create a high-performing, efficient and widely adaptable incubation platform. The featured adjustable fan speed allows users to specify operating parameters to optimize their individual experiments. When the fan is switched off, the evaporation occurring in the incubator is at its lowest. When the fan is set to 100%, the temperature stability and uniformity is optimized.
Gravity Convection

Gravity convection introduces heated air into the bottom of the incubator and gravity causes the warmer air to rise and be distributed throughout the incubator. With less air being displaced, there is no need for a fan because gravity provides the force needed to distribute the warm air that gently heats samples. This convection mode prevents samples from drying out during incubations. Gravity convection technology is ideal for incubation of bacterial and eukaryotic cell cultures, but is limited by the degree to which air can be heated and the time it takes for an incubator to recover after the door is opened.

Mechanical Convection

Mechanical convection utilizes a fan that delivers heated air throughout the incubator creating a uniform temperature distribution throughout the unit. This method provides optimal temperature uniformity and stability due to the rapid distribution of air, which is ideal for bacterial cultures. In addition, mechanical convection is capable of quickly warming samples that have been transferred directly from the refrigerator to the incubator. Many laboratories choose mechanical convection incubators during sample drying to prevent the evaporation of growth media.

Applications for Heratherm Advanced Protocol Security Microbiological Incubators
  • Clinical and Medical labs: microbiological diagnostic testing
  • Pharmaceutical: quality control testing, safety and testing efficacy of manufactured products
  • Food: screening for bacterial contamination
  • Research and biotech labs: bacterial growth, gene expression studies, production of recombinant proteins
Part Number 51028069
51028264
51028070
51028535
51028111
51028327
Model IMH60-S
IMH60-S SS
IMH100-S
IMH100-S SS
IMH180-S
IMH18-S SS
External Dimensions 22.2"W x 20.9"D x 28.3"H 
(565 x 530 x 720 mm)
25.2"W x 32.3"D x 22.2"H 
(640 x 820 x 565 mm)
25.2"W x 36.2"D x 29.1"H 
(640 x 920 x 738 mm)
Internal Dimensions 14.5"W x 13.9"D x 20"H 
(368 x 354 x 508 mm)
18.3"W x 23.9"D x 14.5"H 
(464 x 608 x 368 mm)
18.3"W x 27.9"D x 21.4"H 
(464 x 708 x 543 mm)
Energy Consumption 
at 37°C
23 Watts 30 Watts 36 Watts
Footprint 3.2 sq. ft. (0.3m2) 3.9 sq. ft.(0.9m2) 5.1 sq. ft. (0.47m2)
Chamber Volume 2.3 cu. ft. (66L) 3.67 cu. ft. (104L) 6.3 cu. ft. (178L)
Number of Shelves 2 included (13 max) 2 included (16 max) 2 included (19 max)
Max Shelf Load 55 lbs. (25kg) 55 lbs. (25kg) 65lbs. (30kg)
Rated power 1390 Watts
Max Current 11.6 amps
Temperature Range Ambient 5 °C to 105 °C
Convection Technology Dual Convection
Spatial Temperature Deviation ± 0.6°C at 37°C (uniformity)
Electrical (plug standard) 100 - 240 50/60hz (NEMA 5-15)
Temperature Deviation Over Time (Stability) ± 0.1°C
Certified Decontamination Cycle Yes
Material
  • Epoxy-Coated exterior: 51028069, 51028070, 51028111
  • Stainless Steel exterior: 51028264, 51028535, 51028327
  • Inner Chamber: Stainless Steel on all models
Interface RS232
Certifications/Compliance cCSAus, CE
Warranty Two-Year Manufacturer Warranty